Cathodic corrosion of polycrystalline silicon MEMS

  • Melitta Hon
  • , Frank W. DelRio
  • , John T. White
  • , Martin Kendig
  • , Carlo Carraro
  • , Roya Maboudian

Research output: Contribution to journal › Article › peer-review

17 Scopus citations

Abstract

Microelectromechanical systems (MEMS) commonly operate under high electric fields. When combined with humidity from the environment, corrosion becomes a critical reliability issue. While corrosion at the anode has been previously observed, the cathode is typically unaffected. In this paper, we provide the unusual report of damage occurring at the cathode in polycrystalline silicon MEMS in addition to the more common corrosion damage due to anodic oxidation. Both types of damage are observed in less than 24 h for an electrode spacing of 2 μm under relative humidity of ≥57% and actuation voltage of 100 V. Under cathodic polarization, dissolution of the electrode and formation of oxygen-rich deposits are observed along the perimeter and sidewall of the cathode. This abnormal phenomenon is determined to be electrochemical and chemical in nature. The mechanism and accelerating factors leading to cathodic dissolution are discussed. © 2007 Elsevier B.V. All rights reserved.
Original languageEnglish
Pages (from-to)323-329
Number of pages7
JournalSensors and Actuators, A: Physical
Volume145-146
Issue number1-2
DOIs
StatePublished - Jul 1 2008
Externally publishedYes

Fingerprint

Dive into the research topics of 'Cathodic corrosion of polycrystalline silicon MEMS'. Together they form a unique fingerprint.

Cite this