Abstract
Using deep level transient spectroscopy, the authors have measured the defect spectrum in the collector of a n-p-n bipolar transistor following fast neutron irradiation as well as the gain on the same device. They show that a slow change observed in both the gain and deep level traps in the n -type collector at 300 K are bistable. The transistor gain and the defects can be returned to the postirradiation condition by forward bias at room temperature, i.e., by operating the transistor (gain) or injection through the base-collector diode (defect spectrum). © 2007 American Institute of Physics.
| Original language | English |
|---|---|
| Journal | Applied Physics Letters |
| Volume | 90 |
| Issue number | 17 |
| DOIs | |
| State | Published - May 21 2007 |
| Externally published | Yes |
Fingerprint
Dive into the research topics of 'Defect-driven gain bistability in neutron damaged, silicon bipolar transistors'. Together they form a unique fingerprint.Cite this