Skip to main navigation Skip to search Skip to main content

Evaluation of the accuracy of stopping and range of ions in matter simulations through secondary ion mass spectrometry and Rutherford backscattering spectrometry for low energy heavy ion implantation

  • Michael Titze
  • , Jose L. Pacheco
  • , Todd Byers
  • , Stuart B. Van Deusen
  • , Daniel L. Perry
  • , Duncan Weathers
  • , Edward S. Bielejec

Research output: Contribution to journalArticlepeer-review

15 Scopus citations

Abstract

The freely available "Stopping and Range of Ions in Matter"(SRIM) code is used for evaluating ion beam ranges and depth profiles. We present secondary ion mass spectrometry and Rutherford backscattering experimental results of Si samples implanted with low energy Sb ions to evaluate the accuracy of SRIM simulations. We show that the SRIM simulation systematically overestimates the range by 2-6 nm and this overestimation increases for larger ion implantation energy. For the lowest energy implantation investigated, here we find up to a 25% error between the SRIM simulation and the measured range. The ion straggle shows excellent agreement between simulation and experimental results.
Original languageEnglish
JournalJournal of Vacuum Science and Technology A: Vacuum, Surfaces and Films
Volume39
Issue number6
DOIs
StatePublished - Dec 1 2021
Externally publishedYes

Fingerprint

Dive into the research topics of 'Evaluation of the accuracy of stopping and range of ions in matter simulations through secondary ion mass spectrometry and Rutherford backscattering spectrometry for low energy heavy ion implantation'. Together they form a unique fingerprint.

Cite this