Abstract
The study of thermal effects, both classical and quantum, at cryogenic temperatures requires the use of on-chip, local, high-sensitivity thermometry. Carbon-platinum composites fabricated using focused ion beam (FIB) assisted deposition form a granular structure which is shown in this study to be uniquely suited for this application. Carbon-platinum thermometers deposited using a 24 pA ion beam current have high sensitivities below 1 K, comparable to the best cryogenic thermometers. In addition, these thermometers can be accurately placed to within 10s of nanometers on the chip using a mask-free process. They also have a weak magnetic field dependence, < 3% change in resistance with applied magnetic fields from 0 to 8 T. Finally, these thermometers are integrable into a variety of nanoscale devices due to the existing wide spread use of FIB.
| Original language | English |
|---|---|
| Pages (from-to) | 482-487 |
| Number of pages | 6 |
| Journal | Carbon |
| Volume | 169 |
| DOIs | |
| State | Published - Nov 1 2020 |
| Externally published | Yes |