Skip to main navigation Skip to search Skip to main content

Mid-infrared time-domain spectroscopy system with carrier-envelope phase stabilization

  • Sheng Liu
  • , Thomas S. Mahony
  • , Daniel A. Bender
  • , Michael B. Sinclair
  • , Igal Brener

Research output: Contribution to journalArticlepeer-review

16 Scopus citations

Abstract

We built a mid-infrared time-domain spectroscopy (TDS) system optimized for the 8-12 μm spectral range based on a compact ultrafast Erbium:fiber laser that enables measurements of phase-resolved optical field transients directly in the time domain with high stability and spectral brightness. We achieved long term (>10 h) stability of the TDS signal by using a carrier-envelope-phase locking technique to reduce the timing jitter caused by environmental changes. Time domain measurements of the mid-infrared beam were achieved via electro-optic sampling in a GaSe crystal, using an ultrashort (∼15 fs) output of the fiber laser. Here, we present a full characterization of our TDS system including the dependence of the amplitude and pulse shape of the detected infrared waveforms on the thickness of the GaSe crystals. © 2013 AIP Publishing LLC.
Original languageEnglish
JournalApplied Physics Letters
Volume103
Issue number18
DOIs
StatePublished - Oct 28 2013
Externally publishedYes

Fingerprint

Dive into the research topics of 'Mid-infrared time-domain spectroscopy system with carrier-envelope phase stabilization'. Together they form a unique fingerprint.

Cite this