Abstract
The positions of Ge atoms intermixed in the Si(100) surface at very low concentration are identified using empty-state imaging in scanning tunneling microscopy. A measurable degree of place exchange occurs at temperatures as low as 330 K. Contrary to earlier conclusions, good differentiation between Si atoms and Ge atoms can be achieved by proper imaging conditions. © 2000 The American Physical Society.
| Original language | English |
|---|---|
| Pages (from-to) | 4645-4648 |
| Number of pages | 4 |
| Journal | Physical Review Letters |
| Volume | 84 |
| Issue number | 20 |
| DOIs | |
| State | Published - Jan 1 2000 |
| Externally published | Yes |
Fingerprint
Dive into the research topics of 'Scanning tunneling microscopy identification of atomic-scale intermixing on Si(100) at submonolayer Ge coverages'. Together they form a unique fingerprint.Cite this