Skip to main navigation Skip to search Skip to main content

Size and frequency of defects in silicon MEMS

Research output: Chapter in Book/Report/Conference proceeding › Conference contribution

2 Scopus citations

Abstract

Mechanical testing of thin films for MEMS has progressed from a developmental stage to a point where validated techniques are used to study the behavior of devices and materials at a very fine scale. Tensile data covering a range of sizes and test techniques have been analyzed to examine the distribution of defects that would be responsible for the observed fracture strengths. For each sample, a critical defect size was calculated based on a published fracture toughness and a half-circular surface crack fracture toughness model. For polysilicon produced using the SUMMiT V process in the period 1998-1999, the calculated mean defect size was 115 nm. For polysilicon produced using the MUMPS process, the calculated mean defect size was 389 nm. Copyright © 2002 by ASME.
Original languageEnglish
Title of host publicationASME International Mechanical Engineering Congress and Exposition, Proceedings
Pages573-576
Number of pages4
DOIs
StatePublished - Jan 1 2002
Externally publishedYes

Fingerprint

Dive into the research topics of 'Size and frequency of defects in silicon MEMS'. Together they form a unique fingerprint.

Cite this