Skip to main navigation Skip to search Skip to main content

Total ionizing dose and displacement damage effects on TaO<inf>x</inf> memristive memories

  • D. R. Hughart
  • , S. M. Dalton
  • , P. R. Mickel
  • , P. E. Dodd
  • , M. R. Shaneyfelt
  • , E. Bielejec
  • , G. Vizkelethy
  • , M. J. Marinella

Research output: Chapter in Book/Report/Conference proceedingConference contribution

12 Scopus citations

Abstract

The effects of ionizing radiation and displacement damage on TaO x memristors are evaluated. Devices show little response to 10 keV x-rays up to 10 Mrad(Si). Co60 gamma rays and 4.5 MeV protons did not change the resistances significantly at levels up to 2.5 Mrad(Si) and 5 Mrad(Si) respectively. 105 MeV and 480 MeV protons cause switching of the memristors from high to low resistance states in some cases, but do not exhibit a consistent degradation. 800 keV silicon ions are observed to cause resistance degradation, with an inverse dependence of resistance on oxygen vacancy density. Variation between different devices appears to be a key factor in determining the electrical response resulting from irradiation. The proposed degradation mechanism likely involves the creation of oxygen vacancies, but a better fundamental understanding of switching is needed before a definitive understanding of radiation degradation can be achieved. © 2013 IEEE.
Original languageEnglish
Title of host publicationIEEE Aerospace Conference Proceedings
DOIs
StatePublished - Jun 12 2013
Externally publishedYes

Fingerprint